4C08S-06 - 6 Tenant Doors with Outgoing Mail Compartment - 4C Wall Mount 8-High Mailboxes
Shipping Time
Type: STD-4C
Barcode: 763128166927
Model: 4C08S-06-AB
Description
Florence versatile™ 4C08S-06 - 6 Tenant Doors with Outgoing Mail Compartment - 4C Wall Mount 8-High Mailboxes
The Florence versatile™ 4C08S-06 is a USPS Approved STD-4C wall-mount 8-high mailbox suite with 6 tenant doors and an outgoing mail compartment. Florence 4C mailboxes meet or exceed STD-4C requirements for new construction and major renovations, and they are also ideal for private delivery applications. Preconfigured versatile™ 4C mailbox designs make it easy to plan a centralized mail area for single or multifamily residential and commercial projects.
USPS requirement: The 1:5 parcel-to-tenant ratio (at least one parcel locker for every 5 tenant mailboxes) is a USPS STD-4C requirement for installations with 5 or more tenant mailboxes. The 4C08S-06 has 6 tenant doors and no parcel locker, so pair it with a parcel locker unit (such as the versatile™ 4C08S-1P) when the installation has 5 or more tenant mailboxes.
Technical Specifications
| Model # | 4C08S-06-AB |
| Configuration | 1 outgoing mail compartment, 6 MB1 tenant doors |
| Total mailbox (tenant) compartments | 6 |
| Tenant door height | 3" |
| Product dimensions | 30.25"H x 17.50"W x 17"D |
| Rough opening | 29-5/8" H x 16-1/2" W x 17" D (max, per Florence cut sheet) |
| Minimum wall depth | 17" required |
| Product weight | 44 lbs |
| Construction | Heavy gauge aluminum with 300 series stainless steel components |
| Door identification | Silver adhesive decals with black numbers 1-6 (included); custom decals and engraving available |
Compartment Dimensions
| Quantity | Compartment Name | Compartment Type | Dimensions |
|---|---|---|---|
| 1 | Outgoing Postal | 1H Outgoing | 3"H x 12"W x 15"D |
| 1 | Master Collection | 1H Master | 3"H x 12"W x 15"D |
| 6 | Standard Mail | 1H Tenant | 3"H x 12"W x 15"D |
Product Features
- USPS Approved to STD-4C regulations required for all new construction and major renovation projects
- 4C standard mailboxes are fully-recessed for in-wall mounting (surface mount collar available separately)
- Heavy gauge aluminum construction with 300 series stainless steel components
- Superior strength, corrosion resistance, and exceptional durability for indoor AND outdoor installations
- Front-loading 4C mailbox includes a carrier access door prepared for a USPS arrow lock (installed by local postal officials) for delivery/service to mailbox
- Tenant doors include heavy-duty cam locks, each with three (3) keys
- Outgoing mail collection compartment with slot, anti-fish comb for security, and protective hood located above the access door
- Silver adhesive decals with black numbers 1-6 are included for door identification; custom decals and engraving available
- USPS regulations require a minimum of one parcel locker for every five tenant compartments and one outgoing mail slot per unit
- Factory installed integral trim surrounds mailbox and unique MUCK (multi-unit connector kit) included for easy installation of multiple 4C mailboxes
Watch the Florence Corporation overview of standard product features:
Available Finishes
Choose from eight durable powder coat finishes: Antique Bronze, Black, Dark Bronze, Gold Speck, Postal Grey, Sandstone, Silver Speck, and White.
Installation Documentation
Recessed (In-Wall) Mounting
The versatile™ 4C08S-06 is fully-recessed for in-wall mounting and requires a minimum wall depth of 17". Rough opening: 29-5/8" H x 16-1/2" W x 17" D. Summary of the Florence 4C Recessed Mount Installation Manual (206362):
- Required tools: cordless driver/drill, 3/8" drill bit, 1/4" and 3/8" socket wrench or nut driver, Phillips and flat blade screwdrivers, T20 Torx bit and bit tip holder.
- Open the right master door until the hold-open arm engages and install the included #8 x 2" pan-head T20 Torx wood screws (K64225) along the right-hand outer frame.
- Partially open the left master door until the right master door can be completely closed.
- Open the left master door until the hold-open arm engages and install screws along the left-hand outer frame.
- With both master doors open and hold-open arms engaged, install screws along the top and bottom frame. Tighten to a snug fit only; overtightening can hinder functionality. If overtightened, back out the screw.
- Multiple modules can be ganged using Florence's exclusive Multi-Unit Connector Kit.
Safety advisories from the manual: Florence 4C units are heavy - use caution when lifting and carrying. Do not stand units up without support to prevent tipping. Units are front-heavy when the master doors are open and must be braced or held in place until secured to the framing. Keep fingers and hands clear of the rough opening pinch hazard. Full manual: 4C Recessed Mount Installation Manual (PDF).
Surface Mounting (with SM08S Surface Mount Collar)
Important: Surface-mounted 4C mailboxes must be approved by your local post office before installation. Many local post offices do not approve surface-mount installations, so confirm with your local USPS officials before ordering the SM08S collar.
Watch the Florence Corporation product overview of the STD-4C Surface Mount Series:
Where in-wall recessing is not possible, the 4C08S-06 can be surface mounted on the face of the wall using the Florence SM08S single column surface mount collar (sold separately, for versatile™ 4C front-loading modules). Summary of the Florence 4C Surface Mount Collar Installation Manual (206363):
- Required tools: cordless driver/drill, 3/8" socket wrench or nut driver, Phillips and flat blade screwdrivers, T20 Torx and 15IP Torx+ screwdrivers/bits.
- Assemble the collar: secure the two side panels to the back panel with #10-32 x 1/2" BHCS T20 Torx screws (48291), one per hole, then attach the top and bottom panels with three screws per side panel and one per hole along the back panel.
- Determine the mounting height using the USPS installation requirements below, then locate and mark at least two (2) 2x4 or greater wood studs.
- Hold the collar against the wall and install two (2) #8 x 2" pan-head T20 Torx wood screws (64225) per slot row, one in each stud.
- Place the 4C module into the collar opening until the trim is flush against the collar surface, then secure the module to the collar with #8-32 x 1" BHMS 15IP Torx+ Taptite II screws (64635): along the right and left outer frame members (master doors open, hold-open arms engaged), plus four (4) along the top and four (4) along the bottom.
- The included mounting screws are intended for a conventionally constructed wood-stud wall; for other surfaces the installer must use proper hardware, and the wall must support the weight of the collar, mailbox, and contents.
Full manual: 4C Surface Mount Collar Installation Manual (PDF).
USPS Installation Height Requirements
- At least one customer compartment must be positioned less than 48" from the finished floor.
- No customer compartment (interior bottom shelf) may be positioned less than 28" from the finished floor.
- No parcel locker compartment (interior bottom shelf) may be positioned less than 15" from the finished floor.
- No tenant lock may be located more than 67" above the finished floor.
- The USPS Arrow lock must be located between 36" and 48" above the finished floor.
Manufacturer Resources
- 4C 8-High Family Cut Sheet (PDF)
- 4C Recessed Mount Installation Manual (PDF)
- 4C Surface Mount Collar Installation Manual (PDF)
- Florence Corporation product page: versatile™ 4C08S-06
ADA Compliance
ADA accessibility for centralized mailboxes is based on wheelchair reach ranges in the 2010 ADA Standards for Accessible Design (Sections 308.2.1 and 308.3.1): usable compartments must sit between 15" minimum and 48" maximum above the finished floor (AFF), and at least 5% of tenant compartments must be compliant. USPS-STD-4C separately requires at least one customer compartment below 48" AFF, no patron lock above 67" AFF, and the USPS arrow lock between 36" and 48" AFF. Local building codes can add requirements, so always confirm with your local authorities.
On this unit: the Florence 4C08 series is fully ADA compliant. Installed at standard recessed mounting height per the Florence instructions, all tenant compartments of this 8-high unit fall within the 15"-48" ADA reach range.
SKU Guide
Every variation of this product shares the base model number 4C08S-06, and the SKU suffix tells you the finish:
- 4C08S-06 = Florence versatile™ STD-4C horizontal mailbox, 8-door-high cabinet, 1 outgoing mail compartment, 6 MB1 tenant doors.
- -AB Antique Bronze -BK Black -DB Dark Bronze -GS Gold Speck -PG Postal Grey -SD Sandstone -SS Silver Speck -WH White
- SM08S = optional surface mount collar (sold separately) that installs this 8-high unit on a wall surface without recessing. Requires local post office approval (see above).
Frequently Asked Questions
Is the Florence 4C08S-06 USPS approved?
Yes. The 4C08S-06 is USPS Approved to STD-4C regulations, which are required for all new construction and major renovation projects. It is also ideal for private delivery applications.
Can the 4C08S-06 be surface mounted instead of recessed?
Yes. The unit is built fully-recessed for in-wall mounting, but it can be mounted on the face of a wall with the Florence SM08S single column surface mount collar, sold separately. See the surface mounting instructions above.
Who installs the arrow lock?
For USPS applications, the arrow lock is installed by USPS personnel only - contact your local Post Office to arrange access. USPS personnel need a McGard screwdriver to install and service the postal Arrow-lock cover (available to USPS personnel on the eBuy2 ordering system; Florence does not provide or sell it). For non-USPS private delivery applications, the arrow lock instructions can be disregarded.
How many keys come with each tenant door?
Each tenant door includes a heavy-duty cam lock with three (3) keys.
Can this mailbox be installed outdoors?
Yes. Heavy gauge aluminum construction with 300 series stainless steel components provides corrosion resistance and durability for indoor AND outdoor installations.
What wall depth do I need for recessed mounting?
A minimum wall depth of 17" is required, with a rough opening of 29-5/8" H x 16-1/2" W x 17" D. See the manufacturer cut sheet for full rough opening details.
How many parcel lockers does USPS require?
USPS regulations require a minimum of one parcel locker for every five tenant compartments and one outgoing mail slot per unit.
How are the doors labeled?
Silver adhesive decals with black numbers 1-6 are included for door identification. Custom silver decals with your own numbering (for example 101, 102) are available on request, and engraving is also offered: standard engraving is included at no additional cost, while black- or white-filled engraving carries an additional charge.
Specifications, installation documentation, and resources per Florence Corporation (florencemailboxes.com). California residents see Prop 65 WARNINGS.